Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" plus the theory of "quality the basic, have faith in the main and management the advanced" for Steel Formwork Design, Timber Bridge Design, Single Storey Building Design, Warmly welcome to cooperate and develop with us! we are going to continue to provide product or service with high quality and competitive rate.
Renewable Design for Design Of Cable Stayed Bridge - Net Frame, Heterosexual Structure Class Details entrance – Zhenyuan Detail:

Introduction

The basic units that make up the grid are triangular cone, triangular prism, cube, truncated quadrangle, etc. These basic units can be combined into trigons, quadrilateral, hexagons, circles or any other shape in a planar shape. It has the advantages of space stress, light weight, large rigidity, good seismic performance, etc. It can be used as the roof of gymnasium, cinema, exhibition hall, waiting hall, stadium stand awning, hangar, two-way large column grid structure and workshop.

Classification of grid:

The first type is composed of plane truss systems, which have four forms: two-way orthogonal spatial grid, two-way orthogonal sideways grid, two-way oblique sideways grid and three-way grid.

The second type is composed of quadrangular cone units, with five forms: normal quadrangular cone grid, normal evacuation quadrangular cone grid, oblique quadrangular cone grid, checkerboard quadrangular cone grid and star quadrangular cone grid.

The third category is composed of triangular cone units, with three forms: triangular cone grid, evacuated triangular cone grid and honeycomb triangular cone grid. Shell-type grid structures are mainly divided into cylindrical shell-type grid, spherical shell-type grid and hyperbolic paraboloid shell-type grid according to the form of shell surface. The grid structure is divided into steel grid, reinforced concrete grid and composite grid composed of steel and reinforced concrete according to the materials used, of which steel grid is widely used.

Internal force analysis of grid structure;

Grid structure is a high-order statically indeterminate structure system. In the analysis of plate grid, it is generally assumed that the joints are hinged, and the external load acts on the joints according to the principle of static equivalence, which can be calculated according to the space truss displacement method, i.e. the finite element method of hinged bar system. Simplified calculation methods, such as cross beam system difference analysis method and pseudo-plate method, can also be used to calculate internal forces and displacements. The joints of single-layer shell grid are generally assumed to be in rigid connections and shall be calculated according to the finite element method of rigid connections. The double-layer shell grid can be calculated by the finite element method of hinged bar system. The shell analogy method can also be used to simplify the calculation of single-layer and double-layer shell grids.

Design and structure of grid:

The bar section of the grid structure shall be calculated and determined according to the strength and stability. In order to reduce the calculated length of the compression bar and increase its stability, measures such as adding subdivided bars and supporting bars can be adopted. The joints of plate-type grid and double-layer shell-type grid made of steel mainly include cross plate joints, welded hollow spherical joints and bolted spherical joints. Cross plate joint is suitable for grid structure of section steel members. The connection between bars and joint plate is welded or high-strength bolted. Hollow spherical joints and bolted spherical joints are suitable for grid structures of steel pipe bars. The joints of single-layer shell grid structure shall be able to withstand bending internal forces. Under normal circumstances, the steel consumption of the joints accounts for about 15-20% of the steel consumption of the whole steel grid structure.

Net Frame, Heterosexual Structure Class

26

Plan of Web Bar of Grid

28

Grid Layout Plan

30

Grid Node Diagram

27

Plan of Lower Chord of Grid

29

Design Drawing of Three-Dimensional Joints of Grid


Product detail pictures:

Renewable Design for Design Of Cable Stayed Bridge - Net Frame, Heterosexual Structure Class Details entrance – Zhenyuan detail pictures


Related Product Guide:

With the "Client-Oriented" business philosophy, a rigorous quality control system, advanced manufacturing equipment and a strong R&D team, we always provide high quality products, excellent services and competitive prices for Renewable Design for Design Of Cable Stayed Bridge - Net Frame, Heterosexual Structure Class Details entrance – Zhenyuan, The product will supply to all over the world, such as: Dominica, Zurich, Zurich, We have gained a lot of recognition among customers spread all across the world. They trust us and always give repetitive orders. Furthermore, mentioned below are some of the major factors that have played significant role in our tremendous growth in this domain.
  • We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Martina from Kuwait - 2018.12.30 10:21
    The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Clara from Angola - 2017.02.14 13:19

    Related Products